New firmware release for R&S®MXO4 oscilloscopes

R&S®MXO4 EMI Application

New firmware release for R&S®MXO4 oscilloscopes

Rohde & Schwarz announces new firmware release for its outstanding oscilloscope series MXO4

On the 10th of July Rohde & Schwarz released the 2.2 (2.2.2.1) version for their MXO4 family of oscilloscopes.

The outstanding features for this version are the already amazing FFT extended from 1 to 4 simultaneous (that can take any analog channel or math as source) and the innovative Zone-Trigger (4 zones, each with up to 8 areas: freely assignable to analog chanels, FFTs and math).

What’s new

  • 2.2.2.1
    • New Features:
      Zone Trigger
      SCPI commands for screen annotations
    • New options:
      Quad-SPI (included in MXO4-K510)
      ARINC (MXO4-K530)
    • New accessories:
      RT-Z2T (Tek probes adapter, level II)
    • Enhancements:
      Quadruple simultaneous FFT
      New dialog for signal color setup
      Switch coarse / fine by pressing multiuse wheel if value in focus
      MXO4-K31: Power Analysis, support for IEC61000-3-2 rev.2019
      MXO4-K31: Power Analysis, magnitude in unit % and A in result table
  • 2.1.3.2
    • New Features:
      Math Formula Editor
      exFAT support
    • New options:
      SPMI (MXO4-K550)
      10Base-T1S (MXO4-K560)
    • New accessories:
      RT-ZM (modular probe)
    • Enhancements:
      Added signal flow diagram in vertical dialog
  • 2.0.3.0
    • New Features:
      DVM (Digital Volt Meter)
    • New options:
      Power Analysis (MXO4-K31)

Download and installation

  • Download the latest firmare from R&S MXO4 firmware download area to the root folder of a USB pen drive.
  • Insure that the instrument is powered and not running any application (you can press the “Preset” button).
      1. Insert the USB key into the scope’s front USB connector and
      2. navigate to:   Menu >> Settings >> Maintenance >> FW Update 
      3. select:  Install from file (button)
      4. from the file browser select USB (sda) device, (double) tap on Setup_MXO4_V2.2.2.1.exe and/or press open button
  • The unit will reboot twice, first into firmware upgrade mode and, when finished, again into normal user mode.

For further details and upgrade instructions please refer to the R&S Release Notes.

WARNING: in the firmware upgrade there is always a risk: instrument must not lose power supply. The process takes a couple of minutes, if you want to be totally safe you can use an UPS.

MXO4-K31: Power Analysis (last chance)

With the previous firmware version 2.0, R&S added the MXO4-K31 option to the MXO4-PK1 bundle. Therefore, new MXO4-PK1s also integrate the MXO-K31, but the same does not apply to existing and already activated/installed ones.

This is an additional reminder (and a limited-time offer) for all our customers who purchased an MXO4 oscilloscope with the MXO4-PK1 bundle before firmware release 2.0.
Please contact us urgently (within the 31th of July) if you would like to freely add the MXO-K31 option to your existing MXO4-PK1 bundle.

Thank you for giving us the opportunity to support your test & measurement needs.